NRC cites Nuclear Management Co. over safety issue at Point Beach plant


June 21, 2002 -- The Nuclear Regulatory Commission staff will meet June 25 in Lisle, Illinois, with representatives of Nuclear Management Company to discuss the safety significance of an inadequate critique of two issues during an emergency preparedness exercise at the Point Beach Nuclear Power Station.

The NRC said a "white" violation of NRC safety regulations had occurred at the plant near Two Rivers, Wisconsin. A "white" code means that it is an issue of low to moderate importance to safety. The two-reactor facility is located near Two Rivers, Wisconsin.

The meeting, called a Regulatory Conference, will seek the utility's evaluation of its significance.

On February 20 a pump in the safety injection system, one of the Unit 2 emergency cooling systems, failed because of a build up of nitrogen gas in the associated piping. The nitrogen had leaked into the piping from the safety injection accumulators, another part of the plant emergency systems which could inject water into the reactor cooling system using pressurized nitrogen in the event of an accident.
The letter transmitting the May 14 report provided the company with an opportunity to request a regulatory conference to discuss this issue. Nuclear Management Company subsequently informed the NRC that it did not contest the "white" characterization of the safety significance of this finding and did not request a meeting with the NRC staff.
In addition to the "white" determination, the NRC issued a Notice of Violation to Nuclear Management Company for failing to take prompt corrective action to prevent the pump failure.
In April 2000 the utility, in response to an Information Notice issued by the NRC, found that the safety injection pumps were susceptible to damage in the event of nitrogen leakage from the accumulators into the safety injection piping. On two subsequent occasions, plant operators observed decreasing levels in the safety injection accumulators, indicating possible nitrogen leakage. Corrective actions, which might have precluded the February 20 pump damage, were not taken.

NRC inspectors also determined that the Point Beach staff offered inadequate critiques of two issues during an emergency preparedness exercise held on February 12. In the first instance, Point Beach staff offered a positive evaluation of participants' Protective Action Recommendation (PAR) to offsite government officials, while the NRC inspectors identified questions the staff's critique had not properly evaluated.

In the second instance, NRC inspectors disagreed with the Point Beach staff's positive evaluation of the participants' decision making on the simulated removal of non-essential personnel, who were not members of the current shift of emergency responders, from the site.

Emergency preparedness exercises are held to identify performance and procedural deficiencies through a critique process to ensure that corrective action takes place before these problems can occur during an actual emergency and have an adverse reaction on public health and safety. To make safety drills effective, the plant staff's critiques of emergency preparedness drills must be thorough and self-critical.

Under its safety significance determination process, NRC officials classify certain conditions at nuclear power plants as being one of four colors which delineate increasing levels of safety significance, beginning with green and progressing to white, yellow or red.
The white finding will result in a future NRC inspection focusing on the plant's corrective action program and its response to the pump failure.

The details of the NRC inspection findings are discussed in Inspection Report 2002-04 which is available online in the NRC's electronic reading room. This report -- with the accession number ML021210488 -- may be viewed in the NRC's ADAMS document system, accessible at http://www.nrc.gov/reading-rm/adams.html.

The final significance determination will be available on the NRC web site at http://www.nrc.gov/what-we-do/regulatory/enforcement/current.html#reactor.

The plant, located to the west of Lake Michigan, is operated by NMC, a nuclear operating company. The plant is owned by Wisconsin Electric Power Co .

Sponsored by FLSmidth

Related Articles

Areva EVOPRO Hungary nuclear power renewable energy Paks nuclear power plant I&C instrumentation and controls

Areva, EVOPRO team on nuclear, renewable energy

Areva and Hungarian engineering company EVOPRO signed a memorandum of understanding to form a global cooperation in nuclear and renewable energy.

Associated Press AP Japan robot Fukushima Daiichi nuclear power plant Hitachi-GE Nuclear Energy

Japan readies first robot to probe melted Fukushima reactor

A snake-like robot designed to examine the inside of one of three melted reactors at the Fukushima Dai-ichi nuclear plant is ready to begin its expedition.

Follow Power Engineering on Twitter
Latest News

S. Africa court dismisses Westinghouse nuclear generator replacement dispute

A South African court dismissed a filing from Westinghouse Electric Co. asking to reopen bidd...

IAEA urges India to tighten nuclear safety regulations

The International Atomic Energy Agency (IAEA) is pressing India to tighten its nuclear safety...

Caterpillar's C280 Genset enters China offshore market

Caterpillar Oil & Gas will supply six of its Cat C280-16 offshore generator sets (gensets...

Justices divided over EPA mercury limits

The Supreme Court's conservative justices cast doubt on the Obama administration's first-ever...

Report: Global wind power installations increased by 42% in 2014

Global wind power installations grew 42 percent year-over-year, according to a new report con...

Low carbon standard passes Ill. Senate committee

An Illinois Senate committee passed a bill that would establish a low carbon standard that wo...

Russia to build two nuclear power reactors in Jordan for $10bn

Russia signed a $10 billion deal to build Jordan’s first nuclear power plant.

Iowa top officials on opposites sides in EPA lawsuit

Iowa's governor and attorney general were on opposite sides of a case argued Wednesday at the...

Power Engineering Current Issue

01/01/2015
Volume 119, Issue 1
1501pe-cover-lg
Products Showcase
Dynamic Fluoride Ion cleaning DFIC of industrial natural gas turbines Hi-Tech Furnace Systems

Dynamic Fluoride Ion Cleaning of IGT Parts

The Dynamic Fluoride Ion Cleaning (DFIC) Process from Hi-Tech Furnace Systems is able to clean deep, narrow cracks of oxides by cycling between negative, atmospheric, and positive pressure.

Archived Articles

2000 | 2001 | 2002 | 2003 | 2004 | 2005 | 2006 | 2007 | 2008 | 2009 | 2010 | 2011 | 2012 | 2013 | 2014 | 2015

Power Industry Wire News

Earthstone Energy, Inc. Reports Fourth Quarter and Full Year 2014 Results

Earthstone Energy, Inc. Reports Fourth Quarter and Full Year 2014 Results

Chicago's Lakeshore Recycling Systems Helps Change a Life on March 27 Airing of the Steve Harvey Show

Chicago's Lakeshore Recycling Systems Helps Change a Life on March 27 Airing of the Ste...

East West Petroleum Corp.'s CEO David Sidoo Interviewed by The Energy Report

East West Petroleum Corp.'s CEO David Sidoo Interviewed by The Energy Report

Perma-Fix Schedules Fourth Quarter 2014 Earnings Conference Call

Perma-Fix Schedules Fourth Quarter 2014 Earnings Conference Call

Murray Energy's Controlling Interest of Foresight Creates U.S. Coal Mining Giant, an Industrial Info News Alert

Murray Energy's Controlling Interest of Foresight Creates U.S. Coal Mining Giant, an In...

Power Engineering

Article Archives for Power Engineering Magazine

Continuing Education

Professional Development Hours

To access a course listing associated to a specific topic listed below, click on the topic of choice from the list below.

Latest Energy Jobs

View more Job Listings >>